Md Mustafa, Md Muziman Syah and Sofian Sauri, Aminul Hakim and Mohd Kamal, Khairidzan and Mokhtar, Mahfuzah (2017) Comparison between point-based and ring-based technologies in keratometric measurement among post myopic laser refractive surgery patients. In: Medical Research Symposium 2017, 10th August 2017, Kuantan, Pahang Darul Makmur, Malaysia.

[img]
Preview
PDF - Published Version
Download (193kB) | Preview

Abstract

Introduction: Corneal power or keratometric value represents two-third of total refractive power of the eye. It is an important parameter in intraocular lens calculation. Purpose of the study was to evaluate repeatability and agreement of keratometric measurements obtained from a six points-based keratometry device; IOLMaster 500 (Carl Zeiss Meditec AG, Jena, Germany) and two Placido disc-based keratometry devices; Atlas Topographer 995 and 9000 models (Carl Zeiss Meditec AG, Jena, Germany). Materials and method: A total of 97 post myopic laser refractive surgery subjects were recruited. Three set of mean corneal power measurements from each device were performed by an examiner in a single visit. The repeatability was evaluated by withinsubject standard deviation, coefficient of variation and intraclass correlation coefficient. A one-way repeated measures analysis of variance was conducted to evaluate keratometric measurement differences between the devices. The BlandAltman analysis was employed to assess inter-device agreement. Results: There were no significant differences of three repeated keratometric measurements in each device (p > 0.05). IOLMaster showed the lowest coefficient of variations in all meridians (< 0.30%).The intraclass correlations were higher than 0.90 in all devices. For inter-device agreement, there were statistically significant differences between Atlas 9000-IOLMaster and Atlas 995-IOLMaster (p < 0.05). The 95% limit of agreement ranged from 0.94 to 1.68. Conclusion: The six points-based technology has a higher repeatability compared to ring based technology in measuring postoperative keratometric measurements. Different keratometry technologies cannot be used interchangeably in clinical setting.

Item Type: Conference or Workshop Item (Slide Presentation)
Additional Information: 4891/62292
Uncontrolled Keywords: higher-order abberation; aberrometry technologies; preoperative laser refractive surgery
Subjects: R Medicine > RE Ophthalmology
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Allied Health Sciences > Department of Optometry and Visual Science
Kulliyyah of Medicine > Department of Ophthalmology
Kulliyyah of Allied Health Sciences
Kulliyyah of Medicine
Depositing User: Dr. Md Muziman Syah Md Mustafa
Date Deposited: 23 Feb 2018 01:04
Last Modified: 26 Apr 2022 08:36
URI: http://irep.iium.edu.my/id/eprint/62292

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year