IIUM Repository

Ocular surface sensitivity repeatability with cochet-bonnet aesthesiometer

Chao, Cecilia and Stapleton, Fiona and Badarudin, Noor Ezailina and Golebiowski, Blanka (2015) Ocular surface sensitivity repeatability with cochet-bonnet aesthesiometer. Optometry and Vision Science, 92 (2). pp. 183-189. ISSN 1538-9235 (O), 1040-5488 (P)

[img] PDF - Published Version
Restricted to Repository staff only

Download (373kB) | Request a copy

Abstract

Purpose. To determine the repeatability of ocular surface threshold measurements using the Cochet-Bonnet esthesiometer on the same day and 3 months apart. Methods. Two separate studies were conducted to determine the repeatability of ocular surface threshold measurements made on the same day (n = 20 subjects) and 3 months apart (n = 29 subjects). The Cochet-Bonnet esthesiometer was used to measure corneal and inferior conjunctival thresholds using the ascending method of limits. The pressure exerted by the Cochet-Bonnet esthesiometer was determined using an analytical balance, for both the 0.08- and 0.12-mm-diameter filaments. This calibration was then used to convert filament length measurements to pressure. Repeatability was determined using a Bland and Altman analysis. Results. The pressure exerted at each filament length differed between the two filament diameters. The measured pressure also differed from values provided by the manufacturer. Repeatability of threshold measurements at the central cornea was shown to be good, with better repeatability for same-day measurements (coefficient of repeatability [CoR] = T0.23 g/mm2) than for those 3 months apart (CoR = T0.52 g/mm2). Threshold measurements at the inferior conjunctiva, in contrast, were poorly repeatable (CoR = T12.78 g/mm2). Conclusions. Cochet-Bonnet esthesiometry is repeatable when performed on the central cornea on the same day and 3 months apart, but this instrument is not recommended for conjunctival threshold measurements. (Optom Vis Sci 2015;92:183Y189) Key Words: Cochet-Bonnet esthesiometer, repeatability, ocular surface sensitivity, corneal mechanical threshold, conjunctival mechanical threshold

Item Type: Article (Journal)
Additional Information: 6235/46135
Uncontrolled Keywords: Cochet-Bonnet esthesiometer, repeatability, ocular surface sensitivity, corneal mechanical threshold, conjunctival mechanical threshold
Subjects: R Medicine > RE Ophthalmology
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Allied Health Sciences > Department of Optometry and Visual Science
Depositing User: Dr Noor Ezailina Badarudin
Date Deposited: 21 Dec 2015 09:53
Last Modified: 21 Dec 2015 09:53
URI: http://irep.iium.edu.my/id/eprint/46135

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year