IIUM Repository

Box–Behnken design based development of UV-reversed phase high performance liquid chromatographic method for determination of ascorbic acid in tablet formulations

Azmi, Syed Najmul Hejaz and Al Hoqani, Umaima and Obaid Said Al Mamari, Juhaina and Mohamed Salim Al Mamari, Buthaina and Sultan Ali Rashid Al Jassasi, Balaqis and Saleh Saif Al Rubaiai, Aziza and Rahman, Nafisur and Nasir, Mohd and Haque, Sk Manirul and Khan, Shah Alam and Ahmed, Qamar Uddin and Zakaria, Zainul Amiruddin (2022) Box–Behnken design based development of UV-reversed phase high performance liquid chromatographic method for determination of ascorbic acid in tablet formulations. Separations, 9 (11). pp. 1-21. E-ISSN 2297-8739

[img] PDF - Published Version
Restricted to Registered users only

Download (2MB) | Request a copy

Abstract

A simple, sensitive, accurate and inexpensive UV-reversed-phase high-performance liquid chromatographic method was developed for the determination of ascorbic acid in tablet formulations. The method was based on the separation of ascorbic acid using a mobile phase of an acetonitrileNaH2PO4 -H3PO4 buffer solution (pH = 3) (5:95 v/v) with a UV detection wavelength of 245 nm and a flow rate of 0.8 mL min−1 at ambient column temperature. The variables of the proposed method, such as acetonitrile fraction (%), flow rate (mL min−1 ) and column temperature (◦C), were optimized on the peak area by response surface methodology via the Box–Behnken design. The mobile phase was passed isocratically, and the separation of ascorbic acid was performed at the retention time of 4.1 min. A calibration graph was obtained and found to be linear in the concentration range of 10–180 µg mL−1 . The method suitability was assessed and an asymmetry factor of 1.15 was obtained. The proposed method was successfully applied for the determination of ascorbic acid in tablet formulations and statistically compared with the results of the reference method. The performance of the proposed method was excellent and in agreement with the reference method. The recovery percentage of the proposed and reference methods was in the range of 99.98–100.04% and showed compliance (100 ± 2%) with regulatory guidelines.

Item Type: Article (Journal)
Uncontrolled Keywords: ascorbic acid; Box–Behnken design; HPLC; ICH; validation
Subjects: Q Science > QD Chemistry
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Pharmacy > Department of Pharmaceutical Chemistry
Kulliyyah of Pharmacy
Depositing User: Dr Qamar Uddin Ahmed
Date Deposited: 16 Nov 2022 16:46
Last Modified: 16 Nov 2022 16:46
URI: http://irep.iium.edu.my/id/eprint/101225

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year