Khan, Ahsan Ali and Nazi Nadin, Mohd Faiz and Mohd Hambiyah, Mohammad Azhadi (2011) Influence of current, spark on-time and off-time on electrode wear during EDM of mild steel. In: Advanced Machining Processes. International Islamic University Malaysia, Kuala Lumpur, Malaysia, pp. 54-58. ISBN 9789674181628
PDF
- Published Version
Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Abstract. The influence of current, spark-on time and off-time on electrode wear during EDM of mild steel with copper electrodes has been presented. As current increases, electrode wear also increases. This behaviour, as it is expected, because high current densities generate large amounts of heat, which rapidly overheats the electrode and causes it to wear. Electrode wear also increases with increase in spark on-time. The effect of the off-time on the electrode wear rate is inversely proportional to the electrode wear rate.