Wai Lee, Jay Wing and Chiew, Yeong Shiong and Wang, Xin and Mat Nor, Mohd Basri and Chase, Geoffrey and Desaive, Thomas (2022) Stochastic integrated model‑based protocol for volume‑controlled ventilation setting. BioMedical Engineering OnLine (BMC), 21 (13). pp. 1-21. ISSN 1475-925X
PDF (Article)
- Published Version
Restricted to Registered users only Download (2MB) | Request a copy |
|
PDF (SCOPUS)
- Supplemental Material
Restricted to Registered users only Download (261kB) | Request a copy |
Abstract
Background and objective: Mechanical ventilation (MV) is the primary form of care for respiratory failure patients. MV settings are based on general clinical guidelines, intuition, and experience. This approach is not patient-specifc and patients may thus experience suboptimal, potentially harmful MV care. This study presents the Stochastic integrated VENT (SiVENT) protocol which combines model-based approaches of the VENT protocol from previous works, with stochastic modelling to take the variation of patient respiratory elastance over time into consideration. Methods: A stochastic model of Ers is integrated into the VENT protocol from previous works to develop the SiVENT protocol, to account for both intra- and inter-patient variability. A cohort of 20 virtual MV patients based on retrospective patient data are used to validate the performance of this method for volume-controlled (VC) ventilation. A performance evaluation was conducted where the SiVENT and VENT protocols were implemented in 1080 instances each to compare the two protocols and evaluate the diference in reduction of possible MV settings achieved by each. Results: From an initial number of 189,000 possible MV setting combinations, the VENT protocol reduced this number to a median of 10,612, achieving a reduction of 94.4% across the cohort. With the integration of the stochastic model component, the SiVENT protocol reduced this number from 189,000 to a median of 9329, achieving a reduction of 95.1% across the cohort. The SiVENT protocol reduces the number of possible combinations provided to the user by more than 1000 combinations as compared to the VENT protocol. Conclusions: Adding a stochastic model component into a model-based approach to selecting MV settings improves the ability of a decision support system to recommend patient-specifc MV settings. It specifcally considers inter- and intra-patient variability in respiratory elastance and eliminates potentially harmful settings based on clinically recommended pressure thresholds. Clinical input and local protocols can further reduce the number of safe setting combinations. The results for the SiVENT protocol justify further investigation of its prediction accuracy and clinical validation trials.
Item Type: | Article (Journal) |
---|---|
Additional Information: | 5608/96785 |
Uncontrolled Keywords: | Mechanical ventilation, Stochastic modelling, Respiratory mechanics, Decision-making, Model-based protocol, Critical care |
Subjects: | R Medicine > RC Internal medicine > RC82 Medical Emergencies, Critical Care, Intensive Care, First Aid |
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): | Kulliyyah of Medicine Kulliyyah of Medicine > Department of Anaesthesiology & Intensive Care |
Depositing User: | Dr. Mohd Basri Mat Nor |
Date Deposited: | 18 Feb 2022 11:30 |
Last Modified: | 23 Feb 2022 09:55 |
URI: | http://irep.iium.edu.my/id/eprint/96785 |
Actions (login required)
View Item |