Adnan, Nadhratul Wardah and Sayed, Inayatullah Shah (2018) Effects of cervical collar on entrance surface dose, exit surface dose and image quality in plain radiography: a phantom study. International Journal of Allied Health Sciences. E-ISSN 2600-8491 (In Press)
|
PDF
Download (498kB) | Preview |
Abstract
Introduction: Trauma patients presented to emergency department usually come with spinal immobilization device as a precaution and initial pre-management care by emergency medical personnel. These types of patients are at higher risk for suspected cervical fractures and internal injuries. The use of cervical collar raises some issues on radiation dose to the patient and image quality. Therefore, the use of cervical collar in routine trauma patients is questioned by researchers. The purpose of this paper was to investigate the effect of cervical collar on entrance surface dose, exit surface dose and image quality. Methods: Siemens Multix Top CR System and Kyoto Kagaku PBU-50 Body Phantom was used. The phantom was positioned supine on the table couch and was exposed with and without cervical collar. An Anteroposterior (AP) Axial cervical projection was performed and the phantom was also exposed with and without Automatic Exposure Control (AEC) to study the effects on radiation dose and image quality. The dose reading was recorded in all exposures and compared. Images obtained were analyzed for Signal to Noise Ratio (SNR). Results: Lower entrance dose was recorded with cervical collar when the AEC was disabled during the exposure and the results were vice versa when the AEC was enabled. Higher exit dose was calculated when cervical collar was applied to the phantom. Greater signal to noise ratio (SNR) was observed with cervical collar. Conclusions: This study concluded that cervical collar adds to exit dose and without any impact on image quality. The entrance surface dose recorded with cervical collar and AEC disabled was lower compared to when it was removed. The entrance dose recorded with collar and the AEC enabled was higher compared to when it was removed.
Item Type: | Article (Journal) |
---|---|
Additional Information: | 6128/67372 |
Uncontrolled Keywords: | Cervical collar, Radiation Dose, Image quality, Computed radiography (CR). |
Subjects: | Q Science > QC Physics |
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): | Kulliyyah of Allied Health Sciences Kulliyyah of Allied Health Sciences > Department of Diagnostic Imaging and Radiotherapy |
Depositing User: | Dr Inayatullah Shah Sayed |
Date Deposited: | 26 Nov 2018 10:26 |
Last Modified: | 28 Jan 2019 11:33 |
URI: | http://irep.iium.edu.my/id/eprint/67372 |
Actions (login required)
View Item |