Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment

A. H., Hazrin and A., Hizrri and A. A., Anis Syazana and H., Khadijah and Nordin, Noor Faizul Hadry and A., Norhidayah and Mohd Aris, Mohd Shukri (2016) Airborne particulate matters and microorganisms in library: An introduction of disinfection method towards safe and health indoor environment. UNSPECIFIED. UNSPECIFIED. (Unpublished)

[img] PDF
Restricted to Repository staff only

Download (362kB) | Request a copy

Abstract

Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems. Keywords: Indoor air quality (IAQ), laboratory, airborne pollutants, particulate matter (PM), microbes, CFU

Item Type: Monograph (UNSPECIFIED)
Additional Information: 4716/65311
Uncontrolled Keywords: Airborne particulate matters, microorganisms,disinfection,
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
R Medicine > RA Public aspects of medicine > RA1190 Toxicology
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Engineering
Kulliyyah of Science > Department of Biotechnology
Depositing User: Dr Mohd Shukri Mohd Aris
Date Deposited: 31 Oct 2018 10:08
Last Modified: 23 Feb 2023 14:33
URI: http://irep.iium.edu.my/id/eprint/65311

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year