Sidek, Khairul Azami and Khalil, Ibrahim (2013) Enhancement of low sampling frequency recordings for ECG biometric matching using interpolation. Computer Methods and Programs in Biomedicine, 109 (1). pp. 13-25. ISSN 0169-2607
PDF (Enhancement of low sampling frequency recordings for ECG biometric matching using interpolation)
- Published Version
Restricted to Registered users only Download (814kB) | Request a copy |
Abstract
Electrocardiogram (ECG) based biometric matching suffers from high misclassification error with lower sampling frequency data. This situation may lead to an unreliable and vulnerable identity authentication process in high security applications. In this paper, quality enhancement techniques for ECG data with low sampling frequency has been proposed for person identification based on piecewise cubic Hermite interpolation (PCHIP) and piecewise cubic spline interpolation (SPLINE). A total of 70 ECG recordings from 4 different public ECG databases with 2 different sampling frequencies were applied for development and performance comparison purposes. An analytical method was used for feature extraction. The ECG recordings were segmented into two parts: the enrolment and recognition datasets. Three biometric matching methods, namely, Cross Correlation (CC), Percent Root-Mean-Square Deviation (PRD) and Wavelet Distance Measurement (WDM) were used for performance evaluation before and after applying interpolation techniques. Results of the experiments suggest that biometric matching with interpolated ECG data on average achieved higher matching percentage value of up to 4% for CC, 3% for PRD and 94% for WDM. These results are compared with the existing method when using ECG recordings with lower sampling frequency. Moreover, increasing the sample size from 56 to 70 subjects improves the results of the experiment by 4% for CC, 14.6% for PRD and 0.3% for WDM. Furthermore, higher classification accuracy of up to 99.1% for PCHIP and 99.2% for SPLINE with interpolated ECG data as compared of up to 97.2% without interpolation ECG data verifies the study claim that applying interpolation techniques enhances the quality of the ECG data.
Item Type: | Article (Journal) |
---|---|
Additional Information: | 4698/31985 |
Uncontrolled Keywords: | ECG, biometrics, piecewise, polynomial Cubic spline, cubic hermite, interpolation |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices > TK7885 Computer engineering |
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): | Kulliyyah of Engineering > Department of Electrical and Computer Engineering |
Depositing User: | Assoc Prof Dr Khairul Azami Sidek |
Date Deposited: | 10 Sep 2013 16:12 |
Last Modified: | 14 Oct 2013 08:53 |
URI: | http://irep.iium.edu.my/id/eprint/31985 |
Actions (login required)
View Item |