IIUM Repository

A comparative study on indoor air quality (IAQ) between centralised and split unit air conditioning systems in a naval ship

Kamaruddin, Amirul Faiz and Zahaba, Maryam and Tamsi, Nur Sarah Fatihah and Anua, Mohd Khusainy and Hassan, Noor Artika and Nordin, Nur Sazwi and Ariffin, Arman (2024) A comparative study on indoor air quality (IAQ) between centralised and split unit air conditioning systems in a naval ship. Defence S and T Technical Bulletin, 17 (1). pp. 28-36. ISSN 1985-6571 E-ISSN 3009-1896

[img]
Preview
PDF - Published Version
Download (2MB) | Preview
[img]
Preview
PDF (SCOPUS) - Supplemental Material
Download (96kB) | Preview

Abstract

This study determines the compliance of indoor air quality (IAQ) in areas served by different heating ventilation and air conditioning (HVAC) systems in a naval ship, namely centralised and split unit air conditioning systems. A total of nine IAQ parameters, which include physical parameters (temperature, relative humidity (RH) and air movement (AM)), chemical parameters (formaldehyde (CH2O), particulate matters (PM10), total volatile organic compounds (TVOC) and carbon dioxide (CO2)) and biological parameters (total bacterial count (TBC) and total fungal count (TFC) were assessed using calibrated handheld IAQ devices at ten different areas in the ship. The results show that the percentage of compliance is higher in areas served by centralised air conditioning systems as compared to split unit air conditioning systems. The Mann-Whitney test (p-value < 0.05) shows significant difference between the centralised and split unit air conditioning areas for all the IAQ parameters except for temperature. These findings indicate that centralised air conditioning systems, which can introduce fresh air into their served areas contribute to the decrease of concentration of chemical and biological parameters, provided that the units are well maintained.

Item Type: Article (Journal)
Additional Information: 9218/111618
Uncontrolled Keywords: Indoor air quality (IAQ), naval ship, centralised and split unit air conditioning, indoor air sampling, Mann-Whitney test
Subjects: V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Allied Health Sciences
Kulliyyah of Allied Health Sciences > Department of Biomedical Science (Effective:1st July 2011)
Kulliyyah of Engineering
Kulliyyah of Engineering > Department of Biotechnology Engineering
Kulliyyah of Medicine
Kulliyyah of Medicine > Department of Community Medicine (Effective: 1st January 2011)
Kulliyyah of Science
Kulliyyah of Science > Department of Chemistry
Depositing User: Dr Noor Artika Hassan
Date Deposited: 27 Mar 2024 13:08
Last Modified: 03 Sep 2024 15:45
URI: http://irep.iium.edu.my/id/eprint/111618

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year