Utilization of clinical videography technique in the assessment of tear meniscus rising speed

Ithnin, Mohd. Hafidz and Ariffin, Azrin Esmady and Mohd Kamal, Khairidzan (2019) Utilization of clinical videography technique in the assessment of tear meniscus rising speed. In: The 10th MSO Annual Scientific Meeting in conjunction with the 34th Malaysia-Singapore Joint Ophthalmic Congress Secretariat, 22nd-24th March 2019, Kuantan, Pahang. (Unpublished)

[img] PDF (Poster) - Presentation
Restricted to Registered users only

Download (346kB) | Request a copy
[img] PDF (Programme book) - Supplemental Material
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Purpose: The utilization of clinical videography technique in the assessment of dynamic tear meniscus was not explained thoroughly. This study was conducted to assess the rising speed of tear meniscus using clinical videography technique. Method: This cross-sectional study recruited 342 subjects with 642 eyes. Dry eye was indicated if the tear film break-up time was less than 5 seconds and schirmer test with anaesthesia values was less than 5mm/5 minutes The meniscus rising speed was recorded using slit lamp videographer. The tear meniscus rising speeds were measured at 1 (TMRS 1), 2, (TMRS 2), 3 (TMRS 3), 4 (TMRS 4), 5 (TMRS 5) seconds after opening the eye without blinking. Results: 83 eyes were classified in the dry eye group (DEG) while the remaining 559 eyes in non-dry eye group (NDEG) The mean of TMRS at one second (TMRS 1) was 0.44 ± 0.24 mm/second, reduces after holding the blinking for 5 seconds (TMRS 5 = 0.09 ± 0.24 mm/second). There were significant differences between non-dry eye and dry eye groups in TMRS 1, TMRS 2, and TMRS 3 (p < 0.05), but not for TMRS 4 and TMRS 5 (p > 0.05). The rising speeds after 3 seconds of holding blinking was found significantly lower in dry eye group than in non-dry eye. Conclusion: The clinical videography technique can be utilized objectively to assess the tear meniscus rising speed. There is a direct correlation between tear meniscus rising time and dry eye status.

Item Type: Conference or Workshop Item (Poster)
Additional Information: 7611/73576
Uncontrolled Keywords: Tear meniscus rising speed, videography, dry eye
Subjects: R Medicine > RE Ophthalmology
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Allied Health Sciences
Kulliyyah of Allied Health Sciences > Department of Optometry and Visual Science
Kulliyyah of Medicine
Kulliyyah of Medicine > Department of Ophthalmology
Depositing User: Dr Mohd Hafidz Ithnin
Date Deposited: 03 Jan 2020 11:16
Last Modified: 03 Jan 2020 11:26