IIUM Repository

Mislabelling of nicotine content in electronic cigarette liquids in Malaysia: implications on public health

Nik Mohamed, Mohamad Haniki and Ab Rahman, Jamalludin and Draman, Samsul and Kartiwi, Mira and Ab Rahman, Norny Syafinaz and Rahman, Azizur and Syed, Mahmood and Jamshed, Shazia Qasim (2017) Mislabelling of nicotine content in electronic cigarette liquids in Malaysia: implications on public health. The Medical Journal of Malaysia, 72 (supp. 1). p. 31. ISSN 0300-5283

[img]
Preview
PDF - Published Version
Download (152kB) | Preview

Abstract

Electronic cigarette (e-cig) is a battery-operated device which vaporises nicotine solution into a form of inhalable aerosol. The level of nicotine in the liquid for e-cig (e-liquid) may vary and the typical nicotine concentration reported is between 6 to 24 mg of per ml. Based on the National Electronic Cigarette Survey (NECS) 2016, 83.9% of e-cig adult users in Malaysia preferred eliquid with 6 mg/ml nicotine. In Malaysia, nicotine in products other than tobacco is regulated under the Poisons Act 1952, restricting its sale by licensed health professionals only. However, the sale of e-liquid containing nicotine is widespread and vapers are not assured of the accuracy of content versus that on the label of the e-liquid bottle. OBJECTIVE: To determine the actual nicotine concentration in selected e-liquid brands marketed in Malaysia. Methods: Samples (81 brands) obtained from respondents of the NECS 2016 were analysed using gas chromatography mass spectrometry (GC-MS) in selective ion mode (SIM) at a certified laboratory. Results: 15 samples labelled as no or zero nicotine were found to contain nicotine. Nine samples contained level of nicotine higher than what their labels indicated. Interestingly, 57 samples had nicotine concentrations that were lower than that indicated on the labels. The nicotine concentration percentage difference between labelled and result from analysis was found to be as low as from -99.16% to -1.28% in 64 samples, while in 4 samples the difference was higher; 0.083% to 163.0%, and the remaining 13 samples had no mention of nicotine concentration on their labels. Conclusion: Significant discrepancy was detected in nicotine concentration between the labelled and analysed values among the collected e-liquid samples. Strict regulation and enforcement is needed for e-cig liquids to ensure safety of users and compliance to current regulations on nicotine.

Item Type: Article (Meeting Abstract)
Additional Information: 4901/58872
Uncontrolled Keywords: nicotine, electronic cigarette, liquids, public health, Malaysia
Subjects: R Medicine > R Medicine (General)
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Information and Communication Technology
Kulliyyah of Information and Communication Technology

Kulliyyah of Medicine > Department of Family Medicine (Effective: 1st January 2011)
Depositing User: SR NUR FARHANA LATFI
Date Deposited: 30 Oct 2017 12:27
Last Modified: 03 Feb 2018 14:31
URI: http://irep.iium.edu.my/id/eprint/58872

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year