Preload-based starling-like control for rotary blood pumps: numerical comparison with pulsatility control and constant speed operation

Mansouri, Mahdi and Salamonsen, Robert F. and Lim, Einly and Akmeliawati, Rini and Lovell, Nigel H. (2015) Preload-based starling-like control for rotary blood pumps: numerical comparison with pulsatility control and constant speed operation. PLoS ONE, 10 (4). e0121413. ISSN 1932-6203

[img] PDF
Restricted to Repository staff only

Download (445kB) | Request a copy

Abstract

In this study, we evaluate a preload-based Starling-like controller for implantable rotary blood pumps (IRBPs) using left ventricular end-diastolic pressure (PLVED) as the feedback variable. Simulations are conducted using a validated mathematical model. The controller emulates the response of the natural left ventricle (LV) to changes in PLVED. We report the performance of the preload-based Starling-like controller in comparison with our recently designed pulsatility controller and constant speed operation. In handling the transition from a baseline state to test states, which include vigorous exercise, blood loss and a major reduction in the LV contractility (LVC), the preload controller outperformed pulsatility control and constant speed operation in all three test scenarios. In exercise, preload-control achieved an increase of 54% in mean pump flow () with minimum loading on the LV, while pulsatility control achieved only a 5% increase in flow and a decrease in mean pump speed. In a hemorrhage scenario, the preload control maintained the greatest safety margin against LV suction. PLVED for the preload controller was 4.9 mmHg, compared with 0.4 mmHg for the pulsatility controller and 0.2 mmHg for the constant speed mode. This was associated with an adequate mean arterial pressure (MAP) of 84 mmHg. In transition to low LVC, for preload control remained constant at 5.22 L/min with a PLVED of 8.0 mmHg. With regards to pulsatility control, fell to the nonviable level of 2.4 L/min with an associated PLVED of 16 mmHg and a MAP of 55 mmHg. Consequently, pulsatility control was deemed inferior to constant speed mode with a PLVED of 11 mmHg and a of 5.13 L/min in low LVC scenario. We conclude that pulsatility control imposes a danger to the patient in the severely reduced LVC scenario, which can be overcome by using a preload-based Starling-like control approach.

Item Type: Article (Journal)
Additional Information: 5806/42705
Uncontrolled Keywords: blood pumps, pulsatility control, speed operation
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ212 Control engineering
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Engineering > Department of Mechatronics Engineering
Depositing User: Prof. Dr. Rini Akmeliawati
Date Deposited: 28 Apr 2015 09:00
Last Modified: 08 Nov 2017 15:30
URI: http://irep.iium.edu.my/id/eprint/42705

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year