IIUM Repository

Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics

Che Arif, Fatin Amalina and Hilmi, Mohd Radzi and Mohd Kamal, Khairidzan and Ithnin, Mohd. Hafidz (2021) Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics. Malaysian Journal of Medicine and Health Sciences, 17 (3). pp. 252-258. ISSN 1675-8544 E-ISSN 2636-9346

[img] PDF - Published Version
Restricted to Registered users only

Download (141kB) | Request a copy
[img]
Preview
PDF - Supplemental Material
Download (260kB) | Preview

Abstract

Introduction: This study aimed to evaluate the short-term efficacy of two comparable formulation of dual-polymer artificial tears: Systane Hydration preservative (SH) and non-preservative (SHUD) in 60 minutes observation period compared to normal saline. Methods: Fifty participants involved in this prospective, double-masked randomised study. Viscosity and pH of artificial tears were evaluated using rheometer and digital pH-meter prior to tear film assessment. Tear break-up time (TBUT) and tear meniscus height (TMH) were measured at baseline, 5, 15 and 60 minutes after instillation. Tear ferning pattern (TFP) were compared between baseline and 60 minutes after instillation. One-way analysis of variance (ANOVA) and Independent T-test were used to evaluate the effects of SH and SHUD after instillation and comparison between each specific time-interval respectively. P-value of 0.05 was set as the level of significance. Results: The viscosity of SH and SHUD was 26.7cP and 32.73cP re-spectively with pH of 7.85 (SH) and 7.74 (SHUD). Both artificial tears showed significant increment in TBUT between baseline and 15 minutes (SH:5.82±1.063, p=0.01; SHUD:6.02±0.979, p<0.001), and 60 minutes (SH:6.22±0.616, p<0.001; SHUD:6.34±0.658, p<0.001). SHUD demonstrated significant increment in TMH at every measurement taken (0.1996±0.02449, p<0.001 at 5min, 0.2038±0.02276, p<0.001 at 15min and 0.2068±0.02094, p<0.001 at 60min). Likewise, in SH group, significant increment in TMH at 15 minutes (0.1994±0.02325, p<0.001) and 60 minutes (0.2012±0.02379, p<0.001) were noted. Both groups revealed improvement in TFP (both, p<0.001) at 60 minutes. No significant im-provement was noted in control group. Conclusion: Improvement in TMH was prominently faster in SHUD than SH, although both TBUT and TFP revealed comparable tears quality between both artificial tears.

Item Type: Article (Journal)
Uncontrolled Keywords: Artificial tears, Systane Hydration, Tear film quality, Tear film quantity
Subjects: R Medicine > RE Ophthalmology
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Allied Health Sciences
Kulliyyah of Allied Health Sciences > Department of Optometry and Visual Science
Kulliyyah of Medicine
Kulliyyah of Medicine > Department of Ophthalmology
Depositing User: Dr Mohd Radzi Hilmi
Date Deposited: 16 Jul 2024 11:08
Last Modified: 16 Jul 2024 11:08
URI: http://irep.iium.edu.my/id/eprint/113215