Ahda, Mustofa and Utomo, Adhitya Ilham Mukti and Salamah, Nina and Guntarti, Any and Khatib, Alfi and Windarsih, Anjar (2026) Identification of lard adulteration in moisturer creams products using FTIR spectroscopy in combination with chemometrics. Chemical Papers, 80 (1). pp. 1055-1065. ISSN 0366-6352 E-ISSN 2585-7290
|
PDF
- Published Version
Restricted to Repository staff only Download (1MB) | Request a copy |
||
|
PDF
- Supplemental Material
Download (204kB) | Preview |
|
|
PDF
- Supplemental Material
Download (1MB) | Preview |
Abstract
Adulteration of lard in moisture creams may be applied to improve their properties. However, it is forbidden for the Muslim community; therefore, the presence of lard in cosmetic products must be detected. The goal of this study is to determine and identify moisturizing creams using Fourier transform infrared (FTIR) spectroscopy and chemometrics. This study made a clear distinction between moisturizing cream with and without lard. Halal analysis was performed on the moisturizing cream to ensure its Halal status. This study is based on the fat analysis of the products. The fat from the moisturizing cream was extracted with n-hexane and investigated with FTIR spectroscopy at 4000–500 cm−1. The FTIR spectra were analyzed using chemometrics to distinguish between halal and haram moisturizing creams. The PLS method was optimized to identify wavenumbers suitable for classifying halal and haram cream. This study reported that the quantification of lard in moisturizing cream at wavenumbers 1000–1295 cm−1 and 1801–1700 cm−1 led to a high R2 of the calibration model of 1 and the lowest error explained with RMSEE value of 3.274% and a high R2Y of 0.994. Furthermore, the validation model has a high R2 and Q2Y of 0.994 and 0.996, respectively. This PLS model has an excellent differentiation between halal and non-halal fat, meaning moisturizing cream can be distinguished using this method. According to the findings of this study, no lard was found in any of the moisturizing creams evaluated by FTIR spectroscopy and chemometrics. The PLS model can clearly distinguish between halal and non-halal cream at wavenumbers 1000–1295 cm−1 and 1801–1700 cm−1.
| Item Type: | Article (Journal) |
|---|---|
| Additional Information: | Alfi Khatib is the first IIUM author |
| Uncontrolled Keywords: | Moisturizing cream, Classification technique, Halal cream, Partial least method |
| Subjects: | Q Science > QD Chemistry |
| Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): | Kulliyyah of Pharmacy > Department of Pharmaceutical Chemistry |
| Depositing User: | Dr. Alfi Khatib |
| Date Deposited: | 21 Sep 2026 11:00 |
| Last Update: | 21 Sep 2026 11:00 |
| Queue Number: | 2026-09-Q5154 |
| URI: | http://irep.iium.edu.my/id/eprint/131336 |
| Indexed In: | WOS and SCOPUS, ERA, Google Scholar |
Actions (login required)
![]() |
View Item |
