IIUM Repository

Electrical stimulator with mechanomyography-based real-time monitoring, muscle fatigue detection, and safety shut-off: a pilot study

Naeem, Jannatul and Hamzaid, Nur Azah and Azman, Amelia Wong and Bijak, Manfred (2020) Electrical stimulator with mechanomyography-based real-time monitoring, muscle fatigue detection, and safety shut-off: a pilot study. Biomedizinische Technik, 65 (4). pp. 461-468. ISSN 0013-5585

[img] PDF (Evidence from publishers' website for MYRA) - Published Version
Restricted to Repository staff only

Download (1MB) | Request a copy
[img]
Preview
PDF (Scopus) - Supplemental Material
Download (234kB) | Preview

Abstract

Functional electrical stimulation (FES) has been used to produce force-related activities on the paralyzed muscle among spinal cord injury (SCI) individuals. Early muscle fatigue is an issue in all FES applications. If not properly monitored, overstimulation can occur, which can lead to muscle damage. A real-Time mechanomyography (MMG)-based FES system was implemented on the quadriceps muscles of three individuals with SCI to generate an isometric force on both legs. Three threshold drop levels of MMG-root mean square (MMG-RMS) feature (thr50, thr60, and thr70; representing 50%, 60%, and 70% drop from initial MMG-RMS values, respectively) were used to terminate the stimulation session. The mean stimulation time increased when the MMG-RMS drop threshold increased (thr50: 22.7 s, thr60: 25.7 s, and thr70: 27.3 s), indicating longer sessions when lower performance drop was allowed. Moreover, at thr70, the torque dropped below 50% from the initial value in 14 trials, more than at thr50 and thr60. This is a clear indication of muscle fatigue detection using the MMG-RMS value. The stimulation time at thr70 was significantly longer (p = 0.013) than that at thr50. The results demonstrated that a real-Time MMG-based FES monitoring system has the potential to prevent the onset of critical muscle fatigue in individuals with SCI in prolonged FES sessions.

Item Type: Article (Journal)
Additional Information: 4858/81486
Uncontrolled Keywords: FES; KE; MMG; RMS; SCI
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices > TK7885 Computer engineering
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Engineering
Kulliyyah of Engineering > Department of Electrical and Computer Engineering
Depositing User: Amelia Wong Azman
Date Deposited: 29 Jul 2020 09:18
Last Modified: 10 Nov 2020 10:54
URI: http://irep.iium.edu.my/id/eprint/81486

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year