IIUM Repository

Quantitation of pregabalin by pre-column derivatization HPLC with UV detection

Mutalabisin, Muhammad Fathiy and Chatterjee, Bappaditya (2018) Quantitation of pregabalin by pre-column derivatization HPLC with UV detection. In: 4th International Pharmaceutical Research Conference 2018, 25th-26th August 2018, Cyberjaya, Malaysia. (Unpublished)

[img] PDF (Abstract) - Supplemental Material
Restricted to Registered users only

Download (303kB) | Request a copy
[img] PDF (Program book) - Supplemental Material
Restricted to Registered users only

Download (10MB) | Request a copy
[img] PDF (Poster) - Presentation
Restricted to Repository staff only

Download (7MB) | Request a copy

Abstract

Introduction: Pregabalin, a drug used to treat neuropathic pain, cannot be detected in its original form by simple high performance liquid chromatography (HPLC) with UV or fluorescence detector due to absence of chromophore group. Objective: To develop and validate a HPLC method with UV detection by pre-column derivatization reaction. Method: Pregabalin, as in the raw form, was derivatized with ninhydrin to form a chromophoric complex. The reaction steps are mixing pregabalin solution in phosphate buffer (pH 7.4) with ninhydrin followed by heating at 70-75 ⁰C for 20 minutes. The HPLC method developed consists of a C18 separation column (150 mm X 4.6 mm internal diameter), mobile phase (buffer pH 5:acetonitrile, 70:30), 1 ml/min flow rate, 569 nm wavelength of detection and 10 min run time. The method was validated using specificity, linearity, range, precision-accuracy parameters. Results: The derivatization reaction was reproducible and it was observed that ninhydrin amount is an important factor. The method was shown to be specific for determination of the complex. It was linear within concentration range 600 µg/ml to 100 µg/ml with correlation coefficient (R2 ) value >0.99. Accuracy value for 3 levels of quality control sample (500, 300 and 100µg/ml) were more than 90%. Precision of the method was established by less than 2% value of relative standard deviation (RSD) between accuracies of each level of quality control samples. Conclusion: The developed method is capable to quantify pregabalin in bulk formulation. However, it would be applied to quantify the drug in formulation

Item Type: Conference or Workshop Item (Poster)
Additional Information: 6923/68357
Uncontrolled Keywords: Pregabalin, HPLC-UV, Development, Quantification
Subjects: R Medicine > RS Pharmacy and materia medica > RS192 Materia Medica-Pharmaceutical Technology
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Pharmacy
Kulliyyah of Pharmacy > Department of Pharmaceutical Technology
Depositing User: Dr Bappaditya Chatterjee
Date Deposited: 27 Dec 2018 15:47
Last Modified: 27 Dec 2018 15:47
URI: http://irep.iium.edu.my/id/eprint/68357