Raham, Tawfik and Ibrahimy, Muhammad Ibn and Motakabber, S. M. A. (2016) Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems. In: 3rd International Conference on Science and Social Research (CSSR 2016), 6th-7th December 2016, Putrajaya, Malaysia. (Unpublished)

WarningThere is a more recent version of this item available.
[img] PDF - Published Version
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

In recent years, the utility grid system is more essential for the power transmission and distribution system because it cannot produce harmful gases or no discharge waste in the environment. PWM based phase synchronous invert systems are generally utilized in the high efficiency energy supply, long distance and higher power quality. The inverter output voltage depends on the coupling transformer, input sources and invert controllers. An inverter using a three leg IGBT has been designed for utility grid and simulated by using MATLAB2014a. In this paper, both sides of the LCL filters are used for removing the DC ripple current, reducing the noise and synchronous the output phase between inverter and the utility grid. The PWM controller has created pulse signal to control the inverter, electronic switches and precisely synchronize with grid line frequency. This system, the input DC voltage 500V, switching frequency 1.65 kHz, grid frequency 50Hz, 20 km feeder (resistance, inductance and capacitance per unit length, which are 0.1153, 1.05e-3 and 11.33e-09 ohms/km) with 30MW three phase load (active and inductive reactive power which are 30e6 W and 2e6 var) and also a balanced utility grid load of star configuration (00, 1200, and 2400 degree) are considered in the design. On the other hand, three phase transformer consists of three signal phase transformers, normal power 100e3, magnetization resistance and inductance which are 500 pu and 416.67pu are considered in this design. The system conversion efficiency is 99.94% and 99.96%, while the total THD are 0.06% on inverter side and 0.04% on grid side.

Item Type: Conference or Workshop Item (Plenary Papers)
Additional Information: 4637/54245
Uncontrolled Keywords: PSI, Controller, choke coil, LCL filter,Transformer
Subjects: T Technology > T Technology (General)
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Engineering