Edy Sutjipto, Agus Geter and Triwiyanto, A and Aminanda, Yulfian and Fekry Faris, Waleed and Adesta, Erry Yulian Triblas (2011) Visual inspection on premature failure of electric motor bearings. Applied Mechanics and Materials, 84-85. pp. 557-561. ISSN 1660-9336
PDF (Visual Inspection on Premature Failure of Electric Motor Bearings)
Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
All electrical motor or generator bearings can potential suffers from electric erosion. Unfortunately, problems can start after just a few months of running a new electric motor or generator. From visual inspection, it was found that the failure happened on the raceway surface in equal spacing. There may be many reasons for this – heavier loading than has been anticipated, inadequate or unsuitable lubrication, careless handling, ineffective sealing, or fits that are too tight, with resultant insufficient internal bearing clearance. Each of these factors produces its own particular type of damage and leaves its own special imprint on the bearing. Consequently, by examining a damaged bearing such as visual inspection, it is possible, in the majority of cases, to form an opinion on the cause of the damage and to take the requisite action to prevent a recurrence
Item Type: | Article (Journal) |
---|---|
Additional Information: | 4703/4222 |
Uncontrolled Keywords: | Electric motor bearing, premature failure, roller bearing |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): | Kulliyyah of Engineering > Department of Manufacturing and Materials Engineering Kulliyyah of Engineering > Department of Mechanical Engineering |
Depositing User: | Prof Dr Ing yulfian aminanda |
Date Deposited: | 27 Oct 2011 15:40 |
Last Modified: | 21 Jun 2013 15:37 |
URI: | http://irep.iium.edu.my/id/eprint/4222 |