Indoor air quality (IAQ) in a naval ship after refit program: a time variation analysis

Zahaba, Maryam and Tamsi, Nur Sarah Fatihah and Engliman, Nurul Sakinah and Kamaruddin, Amirul Faiz and Hassan, Noor Artika and Ariffin, Arman (2022) Indoor air quality (IAQ) in a naval ship after refit program: a time variation analysis. In: 1st International Conference of Air Quality and Climate Change, AQCC 2021 and 3rd Malaysia Air Quality Annual Symposium, MAQAS 2021, 17-18 November 2021, Virtual, Online.

[img] PDF - Published Version
Restricted to Registered users only

Download (853kB) | Request a copy
[img]
Preview
PDF - Supplemental Material
Download (146kB) | Preview

Abstract

Refurbishments of the ship's external and internal structures are the main scopes of a refit program. These activities may affect the indoor air quality (IAQ) inside ships and increase the indoor air pollutants (IAP) concentrations onboard. Therefore, continuous IAQ monitoring is needed to determine IAP exposure to the ship's crew. This study evaluates the changes in IAQ conditions inside a naval ship over a two-time interval to determine the effect of compliance with the recommended engineering control measures proposed in the first assessment. Following the standard of the Industry Code of Practice on Indoor Air Quality 2010 (ICOP on IAQ 2010), seven IAQ parameters (temperature, relative humidity (RH), carbon dioxide (CO2), respirable particulates/particulate matter (PM10), total volatile organic compounds (TVOC), bacterial count, and fungal count) were measured in two assessment phases. The first phase was conducted after the ship completed the refit program, and the second phase began three months later, following the execution of the recommended engineering control measures. According to the findings of this study, all IAQ parameters improved when compared to the first phase assessment. However, some of the readings were still non-compliance with the standards of ICOP on IAQ 2010. In conclusion, the ship's IAQ parameters were improved following the recommended engineering control measures, although more enhanced approaches were required to ensure all parameters complied with the ICOP on IAQ 2010.

Item Type: Proceeding Paper (Other)
Uncontrolled Keywords: Indoor air quality (IAQ); Naval ship; Engineering control; Ship refit program.
Subjects: BPG Islamic geography
V Naval Science > V Naval Science (General)
V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Engineering
Kulliyyah of Engineering > Department of Biotechnology Engineering
Kulliyyah of Science
Kulliyyah of Science > Department of Chemistry
Depositing User: Dr Noor Artika Hassan
Date Deposited: 02 Jan 2024 12:57
Last Modified: 02 Jan 2024 14:23
URI: http://irep.iium.edu.my/id/eprint/109441

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year