The assessment of thermal comfort performance in bamboo ecotourism infrastructure in the tropical climate of Malaysia

Khairul Nizar, Aina Amira and Sanusi, Aliyah Nur Zafirah and Muhammad, Muhammad Azmeer and Ismail, Mohd Noorizhar and Yusof, Zeenat Begam and Azmin, Aida Kesuma (2023) The assessment of thermal comfort performance in bamboo ecotourism infrastructure in the tropical climate of Malaysia. In: 2nd International Conference on Multidisciplinary Research and Practices (ICMRP-2023), Aston Priority Simatupang Hotel & Conference Center, Jakarta.

[img] PDF (Abstract) - Published Version
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Ecotourism has become a growing trend, offering a platform for raising awareness of environmental issues in the tourism industry. One of the principles of ecotourism is relying on environmentally friendly infrastructure to prevent environmental degradation. The shift towards ecotourism has highlighted the significance of sustainable practice and infrastructure design in tourism. Bamboo is gradually renowned due to its role in carbon sequestration, bringing hope to the natural environment despite the slow acceptance by society. Assessing the thermal comfort performance takes on added value in the context of encouraging bamboo utilization for sustainable practice. As bamboo gains recognition for its potential in environmental protection, its thermal comfort attributes could encourage its adoption in future infrastructure. Hence, this study examines the thermal comfort performance in bamboo buildings in Malaysia using various design approaches in the same microclimate. Fieldwork was conducted to analyze the indoor and outdoor temperatures in three different chalets in Tadom Hill Resort, Banting, namely Gendui Chalet, Semantan Chalet, and Hakka Village. Generally, findings concluded that the indoor temperatures are higher than the indoor thermal conditions indicated in Malaysia Standard, MS1525:2007. Findings also indicate that the maximum temperature reduction is 2.4°C, 4.1°C, and 4.6°C for Gendui Chalet, Semantan Chalet, and Hakka Village, respectively. Ultimately, this study seeks to emphasize the feasibility of bamboo as a likely option for building construction, developing, and improving the ecotourism destinations in Malaysia.

Item Type: Conference or Workshop Item (Other)
Uncontrolled Keywords: Bamboo, Ecotourism, Sustainable practice, Thermal comfort
Subjects: N Fine Arts > NA Architecture > NA2542.35 Environmental aspect of architecture
N Fine Arts > NA Architecture > NA2542.36 Sustainable architecture
Kulliyyahs/Centres/Divisions/Institutes (Can select more than one option. Press CONTROL button): Kulliyyah of Architecture and Environmental Design
Kulliyyah of Architecture and Environmental Design > Department of Architecture
Depositing User: Dr Aliyah Sanusi
Date Deposited: 16 Oct 2023 10:11
Last Modified: 16 Oct 2023 10:39
URI: http://irep.iium.edu.my/id/eprint/107416

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year